Cesvaines Street 15A, Riga
Mon–Fri 9:00 a.m.–6:00 p.m., Saturday 10:00 a.m.–3:00 p.m.
Search on Waze/Google Maps: LEDakcijas.lv
Cesvaines Street 15A, Riga
Mon–Fri 9:00 a.m.–6:00 p.m., Saturday 10:00 a.m.–3:00 p.m.
Search on Waze/Google Maps: LEDakcijas.lv
Cesvaines Street 15A, Riga
Mon–Fri 9:00 a.m.–6:00 p.m., Saturday 10:00 a.m.–3:00 p.m.
Search on Waze/Google Maps: LEDakcijas.lv
Cesvaines Street 15A, Riga
Mon–Fri 9:00 a.m.–6:00 p.m., Saturday 10:00 a.m.–3:00 p.m.
Search on Waze/Google Maps: LEDakcijas.lv
Cesvaines Street 15A, Riga
Mon–Fri 9:00 a.m.–6:00 p.m., Saturday 10:00 a.m.–3:00 p.m.
Search on Waze/Google Maps: LEDakcijas.lv
Cesvaines Street 15A, Riga
Mon–Fri 9:00 a.m.–6:00 p.m., Saturday 10:00 a.m.–3:00 p.m.
Search on Waze/Google Maps: LEDakcijas.lv
Welcome to Ledakcijas
Main menu
Your cart
-
LED apgaismojums tehnikai
-
Apgaismojums
-
Solārās sistēmas un enerģija
-
Videonovērošana un drošība
-
Autobraucējiem un tehnikai
-
Dārzam un pagalmam
-
Garāžai, servisam un instrumenti
-
Mājai, interjeram un sadzīvei
-
Mājdzīvnieku aprīkojums
-
Kabeļi, pagarinātāji, uzlāde
-
Kempings, atpūta un teltis
-
Sports, hobiji un spēles
-
Pārtikas un dzērienu iekārtas (HoReCa)
-
Industriālās iekārtas un lopkopība
Product Catalog
-
LED apgaismojums tehnikai
-
Apgaismojums
-
LED lentes un aksesuāri
-
Apkure, klimats un ūdens
-
Solārās sistēmas un enerģija
-
Dārza roboti un pļāvēji
-
Videonovērošana un drošība
-
Autobraucējiem un tehnikai
-
Dārzam un pagalmam
-
Garāžai, servisam un instrumenti
-
Mājai, interjeram un sadzīvei
-
Mājdzīvnieku aprīkojums
-
Elektronika un datorpreces
-
Kabeļi, pagarinātāji, uzlāde
-
Kempings, atpūta un teltis
-
Sports, hobiji un spēles
-
Pārtikas un dzērienu iekārtas (HoReCa)
-
Industriālās iekārtas un lopkopība
V-TAC
4.6 KW single-phase network inverter. "Sadales Tīkla" verified, registered as V-TAC Exports Limited VT-6605105, available for selection. Five-year warranty. IP66. Pick up in store.
This product will be available for purchase in 2 weeks, but you can pre-order it now to receive a 10% discount!
Registered with the Distribution Network as V-TAC Exports Limited VT-6605105.
Ensures optimal operation: The inverter operates in the appropriate mode without feeding energy back into the grid
Power distribution: Excess power is fed into the grid, but if the load exceeds the generated power, the grid supplies the difference
IP65 protection: The housing is protected against moisture and dust
Natural cooling: Fanless design ensures quiet operation
Grid fault detection: Automatically identifies power grid-related faults
Certification and warranty: Tested and certified in accordance with IEC standards; 5-year warranty from the date of purchase
|
Input (DC)
|
Maximum Input Power |
6 kW
|
|
Maximum Input Voltage |
600V |
|
|
Starting Voltage/Minimum Operating Voltage |
120V / 100V
|
|
|
Maximum Power Point Tracking (MPPT) Voltage Range |
120V–550V
|
|
|
Nominal Voltage for Maximum Power Point Tracking |
360V
|
|
|
Maximum Number of Maximum Power Point Trackers / Number of Trackers per Maximum Power Point |
2/1
|
|
|
Maximum current at the MPPT |
12A |
|
|
Output (AC)
|
Maximum Output Current |
20A |
|
Rated AC Power |
4.6 kW |
|
|
Nominal Network Frequency |
50 Hz / 60 Hz |
|
|
Nominal Line Voltage |
230 V, L+N+PE |
|
|
Power Factor |
≥0.99 (Nominal Power) |
|
|
THDi (Measurement of Harmonic Distortion in the Signal) |
<3% (Nominal Capacity)
|
|
|
Productivity
|
Max. Productivity |
97.8% |
|
Productivity in Europe |
96.8% |
|
|
MPPT Efficiency |
99.9% |
|
|
Defense |
Defense |
DC circuit breaker, AC short-circuit protection, Overload protection, Overvoltage protection, Insulation protection, RCD, Overvoltage protection, Undervoltage protection, Overheating protection, Ground fault detection |
|
Communication
|
Display |
LED (Optional) / LCD (Standard) |
|
System Language |
English / Chinese / German / Dutch |
|
|
Communication |
RS-485 standard |
|
|
Certificates
|
Network Connection Standards |
IEC 61727:2004, IEC 62116:2014, IEC 60068-2-1:2007, IEC 60068-2-2:2007, IEC 60068-2-14:2009, IEC 60068-2-30:2005, IEC 61683:1999, DIN VDE 0126-1-1:2013, DIN VDE V 0124-100:2020, VDE-AR-N 4105:2018, G98:2019, C10/11:2019, AS/NZS 4777.2:2020, NB/T 32004-2018, PEA, ZVR |
|
Safety / EMC |
IEC/EN 62109-1:2010, IEC/EN 62109-2:2011, EN 61000-6-2:2019, EN 61000-6-3:2007/A1:2011 |
|
|
Key Data
|
Dimensions |
360 x 462 x 150 mm |
|
Weight |
18 kg |
|
|
Operating Temperature Range |
-25°C to +60°C (Performance decreases above 45°C) |
|
|
Cooling Method |
Natural cooling |
|
|
Noise level |
<30 dB |
|
|
Defense Standard |
IP65 |
|
|
Highest elevation |
3,000 m (Performance decreases at 2,000 m) |
|
|
Relative Humidity |
0–95% |
|
|
Topology |
Without a transformer |
|
|
Power Consumption at Night |
<1W |
|
|
Warranty |
5 years |
Choose your Location
-
Store
Free order pickup
We prepare orders for pickup within a few hours
15A Cesvaines Street, Riga, LV-1073
📞 +371 200 22 881
🕐
Monday–Friday: 9:00 a.m.–6:00 p. m.
Saturday: 10:00 a.m.–3:00 p.m.
Sunday: Closed
The holiday code is ACTIVE
Use the discount code BRIVDIENA and get an additional 7% off your purchase!
4.6 KW single-phase network inverter. "Sadales Tīkla" verified, registered as V-TAC Exports Limited VT-6605105, available for selection. Five-year warranty. IP66. Pick up in store.
*Offer valid only for purchases made in the online store
In-Store Pickup: Make your payment and, once confirmed, pick up your order at 15a Cesvaines Street, Riga
Delivery
We offer convenient delivery throughout Latvia to Omniva, DPD, or Latvijas Pasts pickup points for €2.99, or delivery by courier to your address for €7.99.
Free delivery to pickup points for orders of €100 or more; free courier delivery for orders of €300 or more.
Warranty
All products in our store come with an official warranty ranging from 2 to 6 years, depending on the manufacturer.
The warranty period is the same for both individuals and businesses!
Share:
Free Shipping
To pickup points starting at €100; by courier starting at €300
30-Day Return Policy
All items must be free of signs of use
Product Description
Registered with the Distribution Network as V-TAC Exports Limited VT-6605105.
Ensures optimal operation: The inverter operates in the appropriate mode without feeding energy back into the grid
Power distribution: Excess power is fed into the grid, but if the load exceeds the generated power, the grid supplies the difference
IP65 protection: The housing is protected against moisture and dust
Natural cooling: Fanless design ensures quiet operation
Grid fault detection: Automatically identifies power grid-related faults
Certification and warranty: Tested and certified in accordance with IEC standards; 5-year warranty from the date of purchase
|
Input (DC)
|
Maximum Input Power |
6 kW
|
|
Maximum Input Voltage |
600V |
|
|
Starting Voltage/Minimum Operating Voltage |
120V / 100V
|
|
|
Maximum Power Point Tracking (MPPT) Voltage Range |
120V–550V
|
|
|
Nominal Voltage for Maximum Power Point Tracking |
360V
|
|
|
Maximum Number of Maximum Power Point Trackers / Number of Trackers per Maximum Power Point |
2/1
|
|
|
Maximum current at the MPPT |
12A |
|
|
Output (AC)
|
Maximum Output Current |
20A |
|
Rated AC Power |
4.6 kW |
|
|
Nominal Network Frequency |
50 Hz / 60 Hz |
|
|
Nominal Line Voltage |
230 V, L+N+PE |
|
|
Power Factor |
≥0.99 (Nominal Power) |
|
|
THDi (Measurement of Harmonic Distortion in the Signal) |
<3% (Nominal Capacity)
|
|
|
Productivity
|
Max. Productivity |
97.8% |
|
Productivity in Europe |
96.8% |
|
|
MPPT Efficiency |
99.9% |
|
|
Defense |
Defense |
DC circuit breaker, AC short-circuit protection, Overload protection, Overvoltage protection, Insulation protection, RCD, Overvoltage protection, Undervoltage protection, Overheating protection, Ground fault detection |
|
Communication
|
Display |
LED (Optional) / LCD (Standard) |
|
System Language |
English / Chinese / German / Dutch |
|
|
Communication |
RS-485 standard |
|
|
Certificates
|
Network Connection Standards |
IEC 61727:2004, IEC 62116:2014, IEC 60068-2-1:2007, IEC 60068-2-2:2007, IEC 60068-2-14:2009, IEC 60068-2-30:2005, IEC 61683:1999, DIN VDE 0126-1-1:2013, DIN VDE V 0124-100:2020, VDE-AR-N 4105:2018, G98:2019, C10/11:2019, AS/NZS 4777.2:2020, NB/T 32004-2018, PEA, ZVR |
|
Safety / EMC |
IEC/EN 62109-1:2010, IEC/EN 62109-2:2011, EN 61000-6-2:2019, EN 61000-6-3:2007/A1:2011 |
|
|
Key Data
|
Dimensions |
360 x 462 x 150 mm |
|
Weight |
18 kg |
|
|
Operating Temperature Range |
-25°C to +60°C (Performance decreases above 45°C) |
|
|
Cooling Method |
Natural cooling |
|
|
Noise level |
<30 dB |
|
|
Defense Standard |
IP65 |
|
|
Highest elevation |
3,000 m (Performance decreases at 2,000 m) |
|
|
Relative Humidity |
0–95% |
|
|
Topology |
Without a transformer |
|
|
Power Consumption at Night |
<1W |
|
|
Warranty |
5 years |
We guarantee a safe shopping experience
Our store carries only products from official manufacturers and distributors that we trust.
Customer Support
Contact us with your question, and we'll help you
Delivery throughout Latvia
We provide delivery throughout Latvia
Secure Payments
We guarantee convenient and secure payments
- Choosing a selection results in a full page refresh.
- Opens in a new window.