FX PROTECT G-FINITY CNT GRAPHENE COATING 30ml - Ceramic graphene body coating

SKU: FXCNT30
Sale price€150,00

Tax included Shipping calculated at checkout

Description


FX PROTECT G-FINITY™ CNT GRAPHENE COATING

PackageīMeet the new superhydrophobic carbonļa-ceramic compound pārklāwith additional carboncarbon nanotubes (CNTs) and lift your carsīthe top of your carūyour carīfullīyoungā līmenī.

PNVIRONMENTAL CHARACTERISTICS

  • Superhydrophobic
  • Bonded to graphene and carbon nanotubes (CNTs)
  • Durability up to 5 years (~60.000km)
  • Quick and easy application
  • Impressive colour saturation
  • Forms a tension within the coating
  • UV protection
  • Improves colour clarity
  • Fills small imperfections in the paint surface
  • Improves slipperiness
  • Protects against dirt and harmful weather conditions

APPLICATIONSURFACE

  • Painted surfaces (bodywork, rims, plastics)
  • Unpainted exterior plastics (mouldings)
  • Vinyl surfaces
  • Rubber surfaces
  • Lights
  • PPF (gloss/matt)


Before first use, test the application of the product on a less visible surface. Improper application may cause unavoidable damage to the surface.

TECHNICAL DATA

Available volumes

15ml, 30ml

HoldsRetention

Up to 5 years (~60.000km)

Chartshade in content

Yes

Carbonin the nonotube content

Yes


Water contact angle

Up to 165°

Hardity

10H

Chemical resistance

2-12 pH

EfficiencyEfficacy

15-20ml
(medium car)

1 layer

Pe coating thickness

Up to 1,25 μm / 1 layer

Self-renewingās

Yes, with 2 layers

ElastElastic coating

Yes

OppMultiple layers possible

Up to 2 layers

(next layer after 4 hours)

ContactEating time

After 12h or IR heating

FullFull curing time

7 days

Recommend torecommended temperature during application

10-25°C

Recommended humidity on applicationduring application

30-70%

IRpossibility of cooling

Yes

RELO-G™ as a topcoat on a freshly applied main coat

After 8-10h or earlier if dried with IR lamps +2h

Safe on freshly coatedon freshly painted surfaces

After 6-8 weeks

Use lSee

Use by the time indicated on the packaging, or within 14 days of opening

StoreStorage temperature

10-20°C

APPLICATION METHODS

Before application of the coating, it is necessary to chemically clean the surface. For best effect and protection, a colour correction is recommended.


Application instructionsInstructions:

  • Clean the surface with a degreasing liquid (we recommend FX PROTECT SURFACE AGENT).
  • Shake well before use.
  • Apply suede microfibre to applicator (included)
  • Apply a few drops of the coating on the prepared applicator
  • Apply evenly on small surfaces (50 cm x 50 cm), longitudinally and transversely using an overlapping motion
  • Remove* residual product with a clean microfibre without seams (cleaning time may vary from 1 to 3 minutes depending on conditions)
  • using a second microfibre, lightly polish the surface to a shine

* remember to remove excess product at the right time. If left for too long it will crystallise and can be very difficult to remove.


Recommendation:

We recommend using a short fluff of quality microfibre:

  • ROYAL CORAL/POLAR WHITE 320gsm
  • MYSTIC BLUE 350gsm
  • BLUE SKY 500gsm

PRODUCT REMOVAL

Once cured, G-FINITY™ CNT GRAPHENE COATING is very difficult to remove from the surface. The product components are inseparably bonded to the paint structure, removal of the protective coating from a painted surface is only possible by deep polishing and sanding (P1500 - P2000).





Safety information:

Signal word: DANGER! Contains: n-butyl acetate, hydrocarbons, C10-C13, n-alkanes, iso-alkanes, cyclic compounds, < 2% aromatics, cyclosilazanes, di-Me, Me hydrogen, polymers with di-Me, Me hydrogen silazanes, reaction products with 3-(triethoxysilyl)-1-propanam, 3-aminopropyltriethoxysilane, dibutyltin dilaurate, methanol.

Hazard statements:

H302 Harmful if swallowed. H304 May cause death if swallowed or enters the respiratory tract. H314 Causes severe skin burns and eye damage. H336 May cause drowsiness or dizziness. H360FD May adversely affect fertility. May cause harm to the unborn child. H412 Harmful to aquatic organisms with long-lasting effects.

Indications of safety requirements:

P101 If medical advice is required, appropriate information is given on the packaging or label. P102 Keep away from children. P280 Use protective gloves/protective clothing/eye protection/face protection. P301+P330+P331 IN CASE OF DANGER: Rinse mouth. DO NOT induce vomiting. P303+P361+P353 IN CONTACT WITH SKIN (or hair): Remove immediately all contaminated clothing. Rinse skin with water or shower. P305+P351+P338 CONTACT WITH EYES: Rinse gently with water for several minutes. Remove contact lenses if they are inserted and if this can be easily done. Continue rinsing. P310 Contact a doctor immediately. P405 Keep closed. P501 Dispose of contents/container by handing over to person responsible for disposal or returning to supplier.

Shipping and returns

You might like it

Recently viewed items