{"product_id":"ajax-12-24v-barosanas-bloks-prieks-hub-2-hub-2-plus-rex-2","title":"Ajax 12-24V Power Supply for Hub 2\/Hub 2 Plus\/ReX 2","description":"\u003cheader class=\"col-12 text-center\"\u003e\n\u003ch1 class=\"\"\u003e12V PSU for Hub 2\/ReX 2 user manual\u003c\/h1\u003e\n\u003c\/header\u003e\n\u003cdiv class=\"col-12\" data-html2canvas-ignore=\"true\"\u003e\n\u003cdiv class=\"post-thumbnail\"\u003e\u003cimg src=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-og-image.jpg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-12 post-content\"\u003e\n\u003cdiv class=\"iframe-container\"\u003e\u003ciframe title=\"How to install a power supply unit into an Ajax hub or range extender\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/eMHa6aeHcW8?feature=oembed\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv class=\"alert\"\u003e\n\u003cdiv class=\"icon\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/themes\/ajax-support\/assets\/icons\/warning.svg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e\u003cstrong\u003e12V PSU for Hub 2\/ReX 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis out of production. The new alternative power supply\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-24V PSU for Hub 2\/Hub 2 Plus\/ReX 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis available for ordering.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/ajax.systems\/products\/12-24vpsu-hub2\/\" rel=\"noopener\" target=\"_blank\"\u003eBuy 12-24V PSU for Hub 2\/Hub 2 Plus\/ReX 2\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/support.ajax.systems\/en\/manuals\/12-24vpsu-hub2\/\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual 12-24V PSU for Hub 2\/Hub 2 Plus\/ReX 2\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e12V PSU for Hub 2\/ReX 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a power supply unit, connecting the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/support.ajax.systems\/en\/manuals\/hub-2\/\" rel=\"noopener\" target=\"_blank\"\u003eHub 2\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003econtrol panels to 12 volt DC sources. This is an electronic board, replacing the standard 110\/230 V power supply unit in the body of the device.\u003c\/p\u003e\n\u003cdiv class=\"hand-link\"\u003e\u003ca href=\"https:\/\/drive.google.com\/file\/d\/1WdKqYOMWnNKoPuqNRVRm1rAIF25JWyKq\/view?usp=drive_link\" rel=\"noopener\" target=\"_blank\"\u003eBuy other accessories for hubs\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"block1\" class=\"anchor-block\"\u003e\n\u003ch2\u003eInstalling\u003c\/h2\u003e\n\u003cdiv class=\"alert\"\u003e\n\u003cdiv class=\"icon\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/themes\/ajax-support\/assets\/icons\/warning.svg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e12V PSU for Hub 2\/ReX 2 should be installed by a qualified electrician only.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eBefore installing the power supply, make sure that the device is disconnected from the mains.\u003c\/p\u003e\n\u003cp\u003eWhen installing the 12V PSU for Hub 2\/ReX 2, follow the general electrical safety rules, as well as the requirements of electrical safety regulatory acts. Never disassemble the device while it is under voltage!\u003c\/p\u003e\n\u003ch4\u003eInstallation process:\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eRemove the screws and take off the device from the SmartBracket mounting panel, shifting it down with force.\n\u003cdiv class=\"wp-block-gallery columns-1\"\u003e\n\u003cdiv class=\"blocks-gallery-item\"\u003e\n\u003cfigure class=\"gallery-item\"\u003e\u003ca href=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-1.jpg\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-1.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eSwitch off the device holding the power button for 2 seconds.\u003c\/li\u003e\n\u003cli\u003eDisconnect power and Ethernet cables.\n\u003cdiv class=\"wp-block-gallery columns-1\"\u003e\n\u003cdiv class=\"blocks-gallery-item\"\u003e\n\u003cfigure class=\"gallery-item\"\u003e\u003ca href=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-2.jpg\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-2.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"alert\"\u003e\n\u003cdiv class=\"icon\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/themes\/ajax-support\/assets\/icons\/warning.svg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003eWait 5 minutes for the capacitors to discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove four screws of the back lid and take it off.\n\u003cdiv class=\"wp-block-gallery columns-1\"\u003e\n\u003cdiv class=\"blocks-gallery-item\"\u003e\n\u003cfigure class=\"gallery-item\"\u003e\u003ca href=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-3.jpg\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-3.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the screws attaching the boards to the device body.\n\u003cdiv class=\"wp-block-gallery columns-1\"\u003e\n\u003cdiv class=\"blocks-gallery-item\"\u003e\n\u003cfigure class=\"gallery-item\"\u003e\u003ca href=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-4.jpg\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-4.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eCarefully remove both boards, keeping them in the same plane and not disconnecting them. There is a connector between boards: do not break it.\n\u003cdiv class=\"wp-block-gallery columns-1\"\u003e\n\u003cdiv class=\"blocks-gallery-item\"\u003e\n\u003cfigure class=\"gallery-item\"\u003e\u003ca href=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-5.jpg\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-5.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisconnect the power supply unit (smaller board) from the mainboard.\u003c\/li\u003e\n\u003cli\u003eConnect 12V PSU for Hub 2\/ReX 2 to the mainboard using the eight-pin connector between them. Do not warp or bend the antennas while replacing the board: this can cause the device to malfunction.\n\u003cdiv class=\"wp-block-gallery columns-1\"\u003e\n\u003cdiv class=\"blocks-gallery-item\"\u003e\n\u003cfigure class=\"gallery-item\"\u003e\u003ca href=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-6.jpg\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-6.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"alert\"\u003e\n\u003cdiv class=\"icon\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/themes\/ajax-support\/assets\/icons\/info.svg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003ePlease note: the board contacts should be plugged in the bottom row of the connector (closest to the board). When connected correctly, the boards are on the same level.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-block-gallery columns-1\"\u003e\n\u003cdiv class=\"blocks-gallery-item\"\u003e\n\u003cfigure class=\"gallery-item\"\u003e\u003ca href=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-8.jpg\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/uploads\/2022\/01\/12v-psu-for-hub-2-rex-2-8.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eReassemble the boards and the device body than tighten the screws.\n\u003cdiv class=\"alert\"\u003e\n\u003cdiv class=\"icon\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/themes\/ajax-support\/assets\/icons\/warning.svg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003eCheck that the battery and its cables are not clamped. When installed properly, the boards stand firmly on all guides and do not stagger. Holding the boards together with the back lid, turn the device over. The SIM card slot, power, and Ethernet sockets should match accurately and fit the corresponding sockets, and the power button should not be stuck.\u003cbr\u003eChange the information about input voltage on the device body to avoid incorrect power connections in the future. Use the special bundled sticker with the instruction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eConnect the power (and Ethernet cable) to the appropriate sockets.\u003c\/li\u003e\n\u003cli\u003eSwitch on the 12 V power source.\n\u003cdiv class=\"alert\"\u003e\n\u003cdiv class=\"icon\"\u003e\u003cimg decoding=\"async\" src=\"https:\/\/support.ajax.systems\/wp-content\/themes\/ajax-support\/assets\/icons\/warning.svg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003eDo not connect the power cable with a voltage that exceeds the acceptable input voltage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eSwitch on the device by holding the power button for 2 seconds.\u003c\/li\u003e\n\u003cli\u003eClose and fix the SmartBracket mounting panel.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSwitch on the device, wait until loading, and check the external power status in the Ajax app. If there is no power, and you are using a terminal adapter, check the polarity of the connected wires. If there is no power even after reconnecting, please contact the Support Service.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"block2\" class=\"anchor-block\"\u003e\n\u003ch2\u003eMaintenance\u003c\/h2\u003e\n\u003cp\u003eThe device does not require technical maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"block3\" class=\"anchor-block\"\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv class=\"hand-link\"\u003e\u003ca href=\"https:\/\/ajax.systems\/products\/specs\/12vpsu-hub2\/\" rel=\"noopener\" target=\"_blank\"\u003eAll technical specifications of 12V PSU for Hub 2\/ReX 2\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"hand-link\"\u003e\u003ca href=\"https:\/\/ajax.systems\/standards\/\" rel=\"noopener\" target=\"_blank\"\u003eCompliance with standards\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"block4\" class=\"anchor-block\"\u003e\n\u003ch2\u003eComplete Set\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eAjax 12V PSU for Hub 2\/ReX 2.\u003c\/li\u003e\n\u003cli\u003eTerminal adapter.\u003c\/li\u003e\n\u003cli\u003eQuick start guide.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"block5\" class=\"anchor-block\"\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003cp\u003eWarranty for the AJAX SYSTEMS MANUFACTURING Limited Liability Company products is valid for 2 years after the purchase.\u003c\/p\u003e\n\u003cp\u003eIf the device does not function correctly, please contact the Support Service first. In half of the cases, technical issues can be solved remotely!\u003c\/p\u003e\n\u003cdiv class=\"hand-link\"\u003e\u003ca href=\"https:\/\/ajax.systems\/warranty\/\" rel=\"noopener\" target=\"_blank\"\u003eWarranty Obligations\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"hand-link\"\u003e\u003ca href=\"https:\/\/ajax.systems\/end-user-agreement\/\" rel=\"noopener\" target=\"_blank\"\u003eUser Agreement\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ledakcijas","offers":[{"title":"Default Title","offer_id":55852875317583,"sku":"367308962","price":23.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/7005\/0487\/files\/367308962.webp?v=1756899145","url":"https:\/\/ledakcijas.lv\/en\/products\/ajax-12-24v-barosanas-bloks-prieks-hub-2-hub-2-plus-rex-2","provider":"Ledakcijas","version":"1.0","type":"link"}